바이오리액터 구성품

제품상세정보

■ 2, 3, 5, 7, 15L Size의 다양한 Bioreactor Components
■ Chemglass

  •  
    Unjacketed glass bioreactor vessel
    Cat. No Model Capacity(L) Vessel Min. working volume (L) Vessel I.D (mm) Overall Height (mm)
    R12-132-010 CLS-1379-01 2 0.5 105 246
    R12-132-013 CLS-1380-01 3 0.5 130 260
    R12-132-016 CLS-1382-01 5 1.0 160 260
    R12-132-019 CLS-1383-01 7 2 160 360
    R12-132-022 CLS-1385-01 15 2.5 222 456
    Unjacketed glass bioreactor Red stained
    Cat. No Model Capacity(L) Vessel Min. working volume (L) Vessel I.D (mm) Overall Height (mm)
    R12-132-025 CLS-1380-R-03 3 0.5 130 260
    R12-132-028 CLS-1383-R-07 7 2 160 360
    • Tripod stand for unjacketed vessel
    Tripod stand for unjacketed vessel
    Cat. No Model Vessel Capacity (L) Replacement Silicone O-Ring
    R12-132-031 CLS-1380-STD3 2-3 CLS-1705-150X4
    R12-132-034 CLS-1382-STD5 5 CLS-1705-177X4
    R12-132-037 CLS-1383-STD7 7 CLS-1705-177X4
    R12-132-040 CLS-1385-STD15 15 CLS-1705-274
    Jacketed glass bioreactor vessel
    Cat. No Model Capacity(L) Vessel Min. working volume (L) Vessel I.D (mm) Overall Height (mm)
    R12-132-043 CLS-1381-01 3 0.5 130 275
    R12-132-046 CLS-1382-30 5 1.0 130 275
    R12-132-049 CLS-1384-01 7 2 160 375
    Tripod stand for jacketed vessel
    Cat. No Model Vessel Capacity
    (L)
    Replacement Silicone O-Ring
    R12-132-052 CLS-1381-STD3 2-3 CLS-1705-150X4
    R12-132-055 CLS-1386-STD5 5 CLS-1705-177X4
    R12-132-058 CLS-1384-STD7 7 CLS-1705-177X4
    Stabilizer bars
    Cat. No Model Description
    R12-132-061 CLS-1385-SBD3 Stabilizer Bars, Set of 3, for 15L stands
    Headplate Assembly Stand
    Cat. No Model Description
    R12-132-064 CLS-1380-100 Headplate Assembly Stand
    Agitator Assembly
    Cat. No Model Vessel Capacity (L) Replacement Silicone O-Ring Length of Shaft through Headplate (mm) Shaft Dia.(mm)
    R12-132-067 CLS-1380-05 2-5 CLS-1705-124 222 8
    R12-132-070 CLS-1383-04 7 CLS-1705-124 300 8
    R12-132-073 CLS-1385-05 15 CLS-1705-131 392 15
    R12-132-076 CLS-1385-35 15 CLS-1705-131 390 8
    • ●CLS-1385-35는 15L reactor에 사용하기 위해 Adapter Plate(CLS-1385-30)가 필요함
    Rebuild Kits for Agitator Assembly
    Cat. No Model Fits Agitator Shaft Size (mm)
    R12-132-079 CLS-1380-05PM CLS-1380-05
    CLS-1383-04
    CLS-1385-35
    8
    R12-132-082 CLS-1385-05PM CLS-1385-05 15
    • ●Agitator assembly를 재조립 하기 위한 O-ring, Seal, Bearing Kit
    Media Bottle, Clear, with Hose barb and GL-45 vented cap
    Cat. No Model Vessel Capacity (mL) Tubing Size for Hose Barb
    R12-132-085 CLS-1423-100 100 1/4"
    R12-132-088 CLS-1423-250 250 1/4"
    R12-132-091 CLS-1423-500 500 1/4"
    R12-132-094 CLS-1423-1L 1000 1/4"
    R12-132-097 CLS-1423-2L 2000 1/4"
    R12-132-100 CLS-1423-5L 5000 1/4"
    R12-132-103 CLS-1423-10L 10,000 1/2"
    Vent Port Assemblies for transfer bottles
    Cat. No Model Description bottle Thread Size
    R12-132-106 CLS-1429-10 Single Port GL-45
    R12-132-109 CLS-1429-20 Two Port GL-45
    R12-132-112 CLS-1429-21 Two Port Angled GL-45
    • Headplate
    Cat. No Model Vessel Capacity (L) Total number of ports Replacement Silicone O-Ring
    R12-132-115 CLS-1379-02 2 16 Total Ports
    (M30 Center, 1 each G-3/4,
    5 each M18, 6 each M10,
    3 each M6)
    CLS-1705-135X4
    R12-132-118 CLS-1380-03 3 18 Total Ports
    (M30 Center, 1 each G-3/4,
    5 each M18, 2 each M12,
    6 each M10, 3 each M6)
    CLS-1705-135X4
    R12-132-121 CLS-1382-03 5 and 7 19 Total Ports
    (M30 Center, 1 each G-3/4,
    5 each M18, 2 each M12,
    10 each M10)
    CLS-1705-260
    R12-132-124 CLS-1385-03 15 19 Total Ports
    (69mm Center Port for Agitator,
    6 each M27, 2 each M12,
    10 each M10
    CLS-1705-373
    Adapter Plate, 15L bioreactor to M30
    Cat. No Model Description
    R12-132-127 CLS-1385-30 Adapter plate, M30
    • Addition and Sampling Vessels
    Cat. No Model Description
    R12-132-130 CLS-1437-B01 Flat Bottom Vessel Complete with 2-Port Drip tube Assembly
    R12-132-133 CLS-1437-B02 Flat Bottom Vessel Only
    R12-132-136 CLS-1429-02 2-Port Drip Tube Assembly with Open Top Cap and Gasket
    R12-132-139 CLS-1428-14 White Silicone Gasket Only
    R12-132-142 CLS-1481-20 Cap, GL-32, Blue, Open Top, PP
    Marine Style Impeller Blades
    Cat. No Model Impeller Type Fits Reactor (L) Fits Shaft Size(mm) Impeller Dia.(mm)
    R12-132-145 CLS-1380-06 Vortex(Down) 2-3 8 43
    R12-132-148 CLS-1380-07 Scoping(Up) 2-3 8 43
    R12-132-151 CLS-1382-05 Vortex(Down) 5-7 8 59
    R12-132-154 CLS-1382-06 Scoping(Up) 5-7 8 59
    R12-132-157 CLS-1385-06 Vortex(Down) 15 15 76
    R12-132-160 CLS-1385-07 Scoping(Up) 15 15 76
    R12-132-163 CLS-1385-36 Vortex(Down) 15 8 76
    R12-132-166 CLS-1385-37 Scoping(Up) 15 8 76
    Rushton Style Impeller Blades
    Cat. No Model Fits Reactor (L) Impeller Diameter (mm) Fits Shaft Size (mm)
    R12-132-169 CLS-1380-08 2-3 48 8
    R12-132-172 CLS-1382-07 5-7 60 8
    R12-132-175 CLS-1385-20 15 76 15
    R12-132-178 CLS-1385-50 15 76 8
    Triple Port Adapter, M18 and M27
    Cat. No Model Thread Size Replacement Silicone O-Ring
    R12-132-181 CLS-1380-09 M18 CLS-1705-20X2
    R12-132-184 CLS-1385-08 M27 CLS-1705-121
    • Thermowell, M10
    Thermowell, M10
    Cat. No Model Fits Reactor (L) Immersion Length (mm) Replacement Silicone O-Ring
    R12-132-187 CLS-1380-11 2-5 200 CLS-1705-85X25
    R12-132-190 CLS-1383-05 7 300 CLS-1705-85X25
    R12-132-193 CLS-1385-10 15 370 CLS-1705-85X25
    Aeration Tube with Porous Sparger, M10
    Cat. No Model Fits Reactor (L) Immersion Dim "A" (mm) Replacement Silicone O-Ring
    R12-132-196 CLS-1379-04 2 236 48 CLS-1705-85X25
    R12-132-199 CLS-1380-12 3 238 50 CLS-1705-85X25
    R12-132-202 CLS-1382-08 5 238 73 CLS-1705-85X25
    R12-132-205 CLS-1383-06 7 330 73 CLS-1705-85X25
    R12-132-208 CLS-1385-11 15 420 93 CLS-1705-85X25
    • ● 위 표에 있는 "A" 치수는 Headplate의 다른 port들에 배치를 위함임
    • ● 위 표에 있는 Replacement O-Ring은 M10 연결용임
    Replacement Sparger Tips
    Cat. No Model Porosity(㎛) Replacement Silicone O-Ring
    R12-132-211 CLS-1380-14 10 CLS-1705-008
    R12-132-214 CLS-1380-15 15 CLS-1705-008
    Air Inlet / Outlet Adapter
    Cat. No Model Thread Size Hose Connection O.D. (mm) Replacement Silicone O-Ring
    R12-132-217 CLS-1380-20 M10 6.35 CLS-1705-85X25
    R12-132-220 CLS-1380-18 M18 12.00 CLS-1705-20X2
    R12-132-223 CLS-1385-27 M27 12.00 CLS-1705-121
    Sampling Tube, Adjustable, M10
    Cat. No Model Fits Reactor (L) Maximum Immersion Length (mm) Replacement Silicone O-Ring
    R12-132-226 CLS-1380-21 2-5 232 CLS-1705-85X25
    R12-132-229 CLS-1383-08 7 325 CLS-1705-85X25
    R12-132-232 CLS-1385-13 15 390 CLS-1705-85X25
    Blind Stoppers
    Cat. No Model Size Replacement
    Silicone O-Ring
    R12-132-235 CLS-1380-22 M6 CLS-1705-010
    R12-132-238 CLS-1380-23 M10 CLS-1705-85X25
    R12-132-241 CLS-1380-24 M12 CLS-1705-111
    R12-132-244 CLS-1380-25 M18 CLS-1705-20X2
    R12-132-247 CLS-1385-14 M27 CLS-1705-121
    R12-132-250 CLS-1380-26 G-3/4 CLS-1705-023
    Sampling Tube, Fixed, M10
    Cat. No Model Fits Reactor (L) Maximum Immersion Length (mm) Replacement Silicone O-Ring
    R12-132-253 CLS-1380-33 2-5 212 CLS-1705-85X25
    R12-132-256 CLS-1383-14 7 315 CLS-1705-85X25
    R12-132-259 CLS-1385-26 15 400 CLS-1705-85X25
    Sampling Tube, Reduced Diameter Fixed, M6
    Cat. No Model Fits Reactor (L) Maximum Immersion Length (mm) Replacement Silicone O-Ring
    R12-132-262 CLS-1380-R-33 2-5 210 CLS-1705-010
    Heat Exchangers
    Cat. No Model Fits Reactor (L) Exchanger Style Replacement Silicone O-Ring
    R12-132-265 CLS-1380-28 2-5 Cold Finger CLS-1705-20X2
    R12-132-268 CLS-1382-11 5 Loop CLS-1705-85X25
    R12-132-271 CLS-1383-12 7 Loop CLS-1705-85X25
    R12-132-274 CLS-1385-16 15 Loop CLS-1705-85X25
    Addition Pipe
    Cat. No Model Fits Reactor (L) Thread Size Replacement Silicone O-Ring
    R12-132-277 CLS-1380-31 2-7 M10 CLS-1705-85X25
    R12-132-280 CLS-1380-40 3-15 M12 CLS-1705-111
    R12-132-283 CLS-1380-51 2-7 M18 CLS-1705-20X2
    Baffle Assembly
    Cat. No Model Fits Reactor (L) Thread Size Replacement Silicone O-Ring
    R12-132-286 CLS-1381-04 2-3 M6 CLS-1705-010
    R12-132-289 CLS-1382-10 5 M10 CLS-1705-85X25
    R12-132-292 CLS-1383-11 7 M10 CLS-1705-85X25
    R12-132-295 CLS-1385-17 15 M10 CLS-1705-85X25
    Air aeration tube, M10
    Cat. No Model Fits Reactor (L) Length of Tube Below the Headplate (mm) Replacement Silicone O-Ring
    R12-132-298 CLS-1379-06 2 226 CLS-1705-85X25
    R12-132-301 CLS-1381-05 3-5 238 CLS-1705-85X25
    R12-132-304 CLS-1384-06 7 330 CLS-1705-85X25
    R12-132-307 CLS-1385-18 15 420 CLS-1705-85X25
    Probe Holder, 12mm, Fixed Height
    Cat. No Model Thread Size Replacement Silicone O-Ring
    Interior Exterior
    R12-132-310 CLS-1381-08 M18 CLS-1705-111 CLS-1705-20X2
    R12-132-313 CLS-1381-09 G-3/4 CLS-1705-111 CLS-1705-023
    R12-132-316 CLS-1385-21 M27 CLS-1705-111 CLS-1705-121
    Probe Holder, 12mm, Adjustable Height
    Cat. No Model Thread Size Replacement Silicone O-Ring
    R12-132-319 CLS-1381-06 M18 CLS-1705-20X2
    R12-132-322 CLS-1381-07 G-3/4 CLS-1705-023
    R12-132-325 CLS-1385-19 M27 CLS-1705-121
    Replacement FKM Compression Ring for 12mm Probe
    Cat. No Model Description
    R12-132-328 1380-027 FKM Compression Ring
    • Probe Holder, 19mm, Adjustable height
    Probe Holder, 19mm, Adjustable Height
    Cat. No Model Thread Size Replacement Silicone O-Ring
    R12-132-331 CLS-1381-10 G-3/4 CLS-1705-023
    R12-132-334 CLS-1385-22 M27 CLS-1705-121
    Replacement FKM Compression Ring for 19mm Probe
    Cat. No Model Description
    R12-132-337 1381-009 FKM Compression Ring
    Septum Holder, M18 and M27
    Cat. No Model Thread Size Replacement Silicone O-Ring
    R12-132-340 CLS-1380-10 M18 CLS-1705-20X2
    R12-132-343 CLS-1385-09 M27 CLS-1705-121
    Replacement Septa
    Cat. No Model Description
    R12-132-346 CLS-1380-014 Silicone Rubber Septum
    Hamilton DO Probes to Fit Bio Reactors
    Electrode System Silver Platinum Combination
    Polarization 670mV ± 50mV
    Output 40 to 80nA in Air at 25℃
    Temperature 0-130℃, Sterilization to 130℃
    Drift at Room Temp Under
    Constant Conditions
    <1% per Week
    Stabilization Time <2 Hours
    Pressure 0-4 Bar
    Wetted Materials Stainless Steel 1.4435, EPDM and Silicone with FDA Approval
    Mounting PG 13.5 Thread
    Electrical Connector Standard 4 Pole T 82/D4
    • DO Probe Standard 4 Pole T82/D4 Connector
    DO Probe Standard 4 Pole T82/D4 Connector
    Cat. No Model Fit Reactor (L) Probe O.D. (mm) Probe Length (mm)
    R12-132-349 CLS-1435-D72 1-5 Liter 12 235
    R12-132-352 CLS-1435-D73 7 Liter 12 320
    R12-132-355 CLS-1435-D74 15 Liter 12 420
    • DO Probe with VP Connector
    DO Probe with VP Connector
    Cat. No Model Fit Reactor (L) Probe O.D. (mm) Probe Length (mm)
    R12-132-358 CLS-1435-D82 1-5 Liter 12 225
    R12-132-361 CLS-1435-D83 7 Liter 12 325
    R12-132-364 CLS-1435-D84 15 Liter 12 425
    • Accessories
    Accessories
    Cat. No Model Description
    R12-132-367 CLS-1435-D88 OxyFerm Membrane Kit
    R12-132-370 CLS-1435-D90 Cathode Assembly for OxyFerm DO Sensors
    R12-132-373 CLS-1435-D91 Electrolyte for OxyFerm FDA Sensors, 50mL
    R12-132-376 CLS-1435-D92 Protective Cap for T82 DO Sensor Autoclaving
    • Hamilton pH Probes Specifications
    Hamilton pH Probes Specifications
    pH Range 0-14
    Electrolyte Pressurized phermlyte
    Pressure Range 0-6 Bar
    Electrical Connector Type K8 - Standard pH Connector Head or VP
    Reference System HAMILTON EVEREF-F, Silver ion barrier included
    Temperature Range Steam Sterilizable/Autoclavable to 266℉(0 to 135℃)
    In-situ Sterilization Up to 100 Cycles under Standard Conditions
    • pH Probe Standard K8 Connector
    pH Probe Standard K8 Connector
    Cat. No Model Fit Reactor (L) Probe O.D. (mm) Probe Length (mm)
    R12-132-379 CLS-1435-P72 1-5 12 225
    R12-132-382 CLS-1435-P73 7 12 325
    R12-132-385 CLS-1435-P74 15 12 425
    • pH Probe with VP Connector
    pH Probe with VP Connector
    Cat. No Model Fit Reactor (L) Probe O.D. (mm) Probe Length (mm)
    R12-132-388 CLS-1435-P77 1-5 12 225
    R12-132-391 CLS-1435-P78 7 12 325
    R12-132-394 CLS-1435-P79 15 12 425
    • Hamilton Visiferm Optical DO Probes Specifications
    Hamilton VisiFerm Optical DO probes Specifications
    Measuring Principle Oxygen dependent luminescence Quenching
    Measuring Range 4ppm to 25ppm
    Response Time < 30 seconds at 25℃
    Autoclavable Yes
    Steam Sterilizable Yes (Max 140℃)
    Pressure Range -1 to 12 Bar
    Probe Diameter 12mm
    Connection to Process PG 13.5 Thread
    Electrical Connection VP8
    Wetted Materials SS 1.4435, Silicone EPDM
    • Hamilton VisiFerm Optical DO Probes
    Hamilton VisiFerm Optical DO Probes
    Cat. No Model Fit Reactor (L) Probe Length (mm)
    R12-132-397 CLS-1434-60 1-5 225
    R12-132-400 CLS-1434-62 7 325
    R12-132-403 CLS-1434-64 15 425
    • Harvest Tube, M10 and M27
    Harvest Tube, M10 and M27
    Cat. No Model Vessel Capacity (L) Replacement Silicone O-Ring
    R12-132-406 CLS-1380-32 3 CLS-1705-85X25
    R12-132-409 CLS-1382-12 5 CLS-1705-85X25
    R12-132-412 CLS-1383-13 7 CLS-1705-85X25
    R12-132-415 CLS-1385-23 15 CLS-1705-121
    • Heating Blankets, 110V
    Heating Blankets, 110V
    Cat. No Model Fits Reactor (L) Wattage Dimensions
    W × L (in.)
    R12-132-418 CLS-1379-08 2 110 2.6 × 11.4
    R12-132-421 CLS-1380-19 3 180 4 × 14.5
    R12-132-424 CLS-1385-12 15 385 10 × 26.2
    • Optional Adapter Cord
    Optional Adapter Cord
    Cat. No Model Description
    R12-132-427 CG-3211-10 Optional Adapter Cord for Heating Blanket, Self-Locking
    • Heating Blankets, 110V with VELCRO®
    Heating Blankets, 110V with VELCRO®
    Cat. No Model Fits Reactor (L) Wattage Dimensions
    W × L (in.)
    R12-132-430 CLS-1380-19V 3 110 3.5 × 14
    R12-132-433 CLS-1383-07V 5-7 178 5 × 18
    R12-132-436 CLS-1385-12V 15 383 10 × 27
    • Replacement Silicone O-Ring
    Replacement Silicone O-Ring
    Cat. No Model I.D × Cross Section(mm)
    R12-132-439 CLS-1705-008 4.47 × 1.78
    R12-132-442 CLS-1705-010 6.07 × 1.78
    R12-132-445 CLS-1705-85X25 8.50 × 2.50
    R12-132-448 CLS-1705-111 10.70 × 2.6
    R12-132-451 CLS-1705-18X3 18.0 × 3.0
    R12-132-454 CLS-1705-20X2 20.0 × 2.00
    R12-132-457 CLS-1705-023 26.7 × 1.78
    R12-132-460 CLS-1705-121 26.6 × 2.62
    R12-132-463 CLS-1705-124 31.4 × 3.30
    R12-132-466 CLS-1705-131 42.5 × 2.62
    R12-132-469 CLS-1705-135X4 135 × 4.00
    R12-132-472 CLS-1705-150X4 150 × 4.00
    R12-132-475 CLS-1705-260 166 × 3.00
    R12-132-478 CLS-1705-177X4 177 × 4.00
    R12-132-481 CLS-1705-373 228 × 5.33
    R12-132-484 CLS-1705-274 253 × 3.53
    • Condensers, Glass and Stainless Steel
    Condensers, Glass and Stainless Steel
    Cat. No Model Type Style Fits Reactor(L) Overall Lenth(mm)
    R12-132-487 CLS-1380-GC1 Glass Bulb-Style 2-5 150
    R12-132-490 CLS-1380-GC2 Glass Bulb-Style 7 250
    R12-132-493 CLS-1385-GC3 Glass Coil-Style 15 250
    R12-132-496 CLS-1380-27 Stainless - 3-5 165
    R12-132-499 CLS-1383-09 Stainless - 7 230
    • Single-Use Bioreactor Accessory Kits
    Single-use Bioreactor Accessory Kits
    Cat. No Model Description
    R12-132-502 CLS-1390-01 Complete Bioreactor Accessory Kits
    R12-132-505 CLS-1390-10 Media Inlet Line Assembly
    R12-132-508 CLS-1390-11 Sparger Line Assembly
    R12-132-511 CLS-1390-12 Condenser Vent Line Assembly
    R12-132-514 CLS-1390-13 Sample Line Assembly
    R12-132-517 CLS-1390-14 Overlay Gas Assembly
    R12-132-520 CLS-1390-15 Tri Port Assembly
    • Sampler, Bioreactor, Aseptic, LACH
    Cat. No Model Description
    R12-132-523 CLS-1399-01 Sampler, Aseptic, Lach, Small
    R12-132-526 CLS-1399-02 Sampler, Aseptic, Lach, Large
    • Stirrer Specification
    Stirrer Specification
    Fits Applikon-Style Vessels 1-7 Liters
    Speed Range 10-800 RPM
    Power 91 (in-oz.)
    Voltage Requirements 110 to 240 VAC, 50-60 Hz
    Wattage 240 Watts Max, Peak 2 Amps
    Operating Temperature Range 5 to 40 ℃
    • Stirrers, Complete, Bioreactors
    Cat. No Model Description
    R12-132-529 CLS-1399-100 Stirrer Motor, Controller and Cable

배송안내

택배 배송을 기본으로 하며 고객님의 요청에 의해 화물로 배송이 가능합니다.
고객님의 요청에 의한 긴급 배송(고속버스 화물, 퀵서비스 등)으로 인한 물류비용은 고객님의 부담입니다.
제품 설치 및 교육이 필요한 경우는 Off-Line으로 본사 기술부와 미리 논의 하시고, 직납 일정등의 협의를 부탁드립니다.

배송 기간

재고가있는 품목에 한하여 입금 확인 후 2일 이내에 발송 됩니다. (입금 확인은 당일 3시 마감되며, 3시 이후 입금 건은 익일 처리 됩니다.)
택배의 경우 일반적으로 발송일로부터 3~7일, 도서/산간/오지 등 교통이 불편한 지역의 경우 4~8일(토.일, 공휴일 제외) 정도 소요됩니다.

불가 항력의 사유(일시품절/제조사로부터의 제품 수급 문제/천재지변 등)로 배송이 지연 될 경우 고객님께 연락을 드리겠습니다.
수입품목의 공급 및 재고 상태는 주문시점에 따라 달라질 수 있으며, 공급이 어려울 경우 주문접수 후 주문이 취소 될 수 있습니다.
재고가 없는 상품의 경우 상품이 입고 된 이후 발송이 가능하므로, 안내 받으신 배송기간 보다 다소 연장될 수 있습니다.
제품 준비 과정에 차질이 생겨 늦어질 경우에는 고객님께 연락을 드리겠습니다.
주문하신 상품은 결제 확인 후 발송됩니다.
결제 후 메일 [ info@lklab.com ]이나 전화 [ 031-573-4952 영업부 1번 ]으로 연락 주시면 더욱 빨리 처리 해 드리겠습니다.

배송 지역

전국 어느 지역이나 배송 가능합니다. (단, 지역에 따라서 배송기간에 다소 차이가 있을 수 있습니다.)

배송 운임

주문 금액 기준 (부가세 별도) 총액 5만원 이상 주문시에는 무료로 배송해 드립니다. (택배기준)
단, 5만원 미만 주문 시 착불 발송되며, 요청에 따라 주문자 사전 결제로 선불 배송 가능합니다.
택배 배송이 불가능한 상품(장비 류 등)이나, ‘운임비 별도’로 명시 된 상품, 고객요청에 의한 운동수단 이용 시 배송비는 주문자 부담으로 진행됨에 유의 해 주시기 바랍니다.

배송 확인 방법

My Page의 주문/배송 내역에서 확인 가능합니다.

교환 및 반품 안내

상품에 하자가 있거나 주문한 상품과 다를 경우, 수령일로부터 15일 이내인 경우에 한하여 1:1 상품교환 또는 전액 환불 조치 해드리며,
이에 소요되는 모든 비용 또한 (주)엘케이랩코리아에서 부담합니다.
제품에 하자는 없지만, 다른 상품으로 교환하거나 반품하고자 할 경우, 수령일로 부터 15일 이내이며 사용하지 않은 새 제품인 경우에 한하여 조치해 드립니다.
이에 소요되는 비용은 고객님 부답니다. (제품 사용 후 변심에 의한 교환 및 환불은 불가)
제품의 교환 및 반품 시에는 상품 비닐 및 박스(Brand Box)를 수령하신 상태 그대로 보존하고 있을 경우에만 가능합니다.
교환 및 반품 택배 보내실 때 상품 박스(Brand Box)가 손상되지 않도록 반드시 외부에 박스 한 겹 더 포장 부탁드립니다.

교환 및 반품, 환불이 불가능 한 경우

1. 이용자에게 책임이 있는 사유로 제품이 훼손된 경우
2. 이용자의 사용 또는 일부 소비에 의하여 재화 등의 가치가 현저히 감소한 경우
3. 제품의 포장(비닐 및 상품박스)을 훼손 한 경우
4. 주문 당시 재고가 없어서 국내 / 해외 조달 분 중 수입 발주 되어진 상품
* 재고 상품이 아닌 경우, 수입 발주 되어진 상품의 주문 취소도 불가

환불 안내

현금 결제의 경우 구매자의 이름(또는 회사명)으로 개설된 은행계좌로 송금되며, 카드 결제의 경우 카드 승인 취소로 조치 해 드립니다.